Seitenansicht 1
SPEC SHEET
Keypad Expansion Bus -
You can connect any combination
of Security Command Keypads,
6155LX PIRs, 5845LX
Glassbreaks, or 711, 714, 0r 715
Zone Expanders. Up to 32 zones
with all eight devices.
10 Zones
460 Interface Adapter
Model 462N, 462P, 462FM, 472,
or 481 Interface Cards
XR200 COMMAND
PROCESSOR SYSTEM
Keypad Expansion Bus
FIRE
PIR
850S or
850D
Manual
Pull
FIRE
Window
Contact
600
Series
Heat
Detector
Roll-Up
Doors
821
Strobe
806 Fire
Bell
716 Output
(relay)
Expander
Smoke and Heat Detector Circuits
715
Zone
Expander
714
Zone
Expander
Exterior
Lighting
6155LX
PIR
Single 4-wire
Cable
Single 4-wire
Cable
801 Alarm
Horns
Up to 100 zones and
relays on each
expansion bus
Window Contact
Door
Contact
717 Graphic
Annunciator
Module
LX-Bus
TM
Expansion
*
**
*
*
*
*
*
*
*
*
*
*
*
*
Graphic Annunciator
PIR
6155LX
PIR
90
1234
56
7
8
POWER
ARMED
1076-C
Door
Contact
521LX(T)
Smoke
Detector
711 Zone
Expander
770 and 771
Security Command
Keypads
790, 791, and 793
Security Command
Keypads
Window
Contact
5845LX
Glassbreak Detector
H
H
H
S
S
S
H
711
Zone
Expander
Window
Contact
S
714-16
Zone
Expander
715
Zone
Expander
715-8
Zone
Expander
331 Door
Contact
850S or
850D
Manual
Pull
733 Wiegand
Interface
Proximity Reader or
Magnetic Stripe
Reader
Proximity Reader or
Magnetic Stripe
Reader
COMMUNICATION
The XR200 is unmatched in communication
capability with its digital dialer, multiplex,
cellular, data network communication over
bank data, long-range radio networks, and
the Internet. Also, the XR200 can report to
one or two DMP receivers. DMP Serial 3
SDLC format supports 16-character user,
zone, and area names to increase the
central station’s response time and limit
their dependence on a computer database
for message conversion.
You can also choose Modem IIe and Contact
ID reporting to non-DMP receivers to meet
a range of installation and monitoring
requirements.
EXPANDED HOST OPTIONS
The XR200 features enhanced host options
that provide host backup, customizable
check-in times, retry times, and much
more. By enabling the host backup, the
panel can send messages via a second 462N
card or a second network device, such as a
DMP iCOM™ Internet Alarm Router.
DIGITAL DIALER/MULTIPLEX
The XR200 panel sends alarm and system
reports to the central station using the
super fast SDLC communication format.
SDLC has an average on-line time of 5.6
seconds, which complies with the 6-second
minimum time requirement for savings
plans offered
by long distance carriers.
The XR200 panel’s multiplex capability
allows you to meet requirements for
installations where UL AA multiplex
communication is either required or a
viable option.
SECURE-COM™ AND
CELL-MISER™
The XR200 also allows you to use the DMP
Secure-Com™ cellular phone system for
primary or backup communication of alarm
and system events to the central station.
Additionally, the program option Cell-
Miser™ allows the panel to restrict calls to
alarm, trouble, abort, recall test, and
delayed event reports over the Secure-Com
cellular system.
PAGER DIRECT™ PAGING
The XR200 can send alarm, trouble,
opening, closing, or late to close reports
directly to a user’s pager. Pager Direct™ is
a significantly important feature for
working parents wanting to confirm their
children’s safe arrival home from school.
EVENTS MANAGER
You can also save up to 66% of your
monitoring costs with the XR200 panel by
using its Events Manager option. This
feature allows the panel to buffer specific
system reports and automatically download
them to the receiver when the available
memory is full or keep them in memory
until you download them with Remote
Link™.
TRUE AREAS
The XR200 contains 20 completely
independent programmable areas with
separate account numbers, auto arming
and disarming, armed output relays,
schedules, opening/closing reports, and
Bank Safe and Vault or Common Area
operation.
AREA PARTITIONING
The 20 areas on the XR200 are grouped
into four partitions. Each partition provides
common operating modes, exit delays,
burglary outputs, and closing code options.
AREA, ALL/PERIMETER, AND
HOME/SLEEP/AWAY ARMING
The XR200 also allows you to program
each partition for the following operating
modes: In area mode, each area has
a separate name and account number.
All/Perimeter provides one perimeter and
one interior area. Home/Sleep/Away
provides an interior area, exterior area,
and a bedroom area that can be left off
during sleeping hours.
COMMON AREAS
One or more areas in an Area arming
partition can be designated as common
areas. These areas automatically arm when
the last regular area in the partition is
armed and disarm when the first regular
area is disarmed. This is ideal for lobbies or
areas where users need common access to
specific areas only.
ZONE EXPANSION
The XR200 provides up to 242 zones you
can program for a variety of burglary and
fire applications. The panel contains 8
burglary zones and 2 Class B 12 VDC
powered zones. In addition, there are up
to 32 zones available on the 8 keypad
addresses and up to 200 zones can be
added using two or more Expansion
Interface Cards. The interface cards can
plug directly into the panel or into a Model
460 Interface Adaptor Board. The 460
adaptor plugs into the expansion connector
of the XR200 and provides 5 expansion
interface card slots.
OPTIONAL INTERFACE CARDS
462P Printer Card allows you to connect a
serial printer and provide real-time
80-character printout of system events.
462N Network Card allows you to connect
the XR200 panel to a computer data
network or long-range radio network for
extremely fast communication, or to a
computer for local programming with
Remote Link.
462FM 9600 Baud Modem Card enhances
the panel’s internal modem to 9600 Baud.
472 Inovonics 900MHz Card supports up
to 200 wireless zones including 900 MHz
transmitters.
481 LX-Bus Card provides one LX-Bus™
circuit for up to 100 expansion zones.
485 Access Control Expansion Card
increases memory capacity to 1000 users,
1200 events and 16 door access locations.
Access control features include holiday
schedules, anti-passback operation and
shift schedules.
Note: The 485 Card does not supply an